- #1601 Allow literal (RFC2732) IPv6 addresses in TCP URI (@spike77453)
- #1609 Fix transitionTime not always present in genScenes recall (@Nerivec)
This release adds support for 0 devices:
@xion2000 thank you very much to made this and info where to place this in the system. It worked for me too. The only thing which is not showing is the battery, I don't have it connected with an USB-C cable but working with 3x AAA batteries. Is there a possibility to have this info working in your file?
I have mine working of batteries only also and have the same problem with batteries NOT showing in Zigbee2MQTT unfortunately
Buonasera a tutti, chiedo gentilmente se è possibile aggiungere il seguente dispositivo:
export default {
zigbeeModel: ['TS0601'],
model: 'TS0601',
vendor: '_TZE204_o9d1hdma',
description: 'Automatically generated definition',
extend: [],
meta: {},
};
il dispositivo in questione è praticamente identico ad un dispositivo presente nella lista dispositivi supportati, ne ho 6 in casa mi piacerebbe tantissimo vederli funzionare
https://www.zigbee2mqtt.io/devices/AE-669K.html
Grazie per il vostro prezioso aiuto
Mattia
Bonjour
Pouvez vous ajouter cet appareil SMT10020 de schneider svp, c'est un capteur d'echauffement des cables
Hi can you add motion and light sensor.
This is the generated external converter :
const {identify, iasZoneAlarm, battery, illuminance} = require('zigbee-herdsman-converters/lib/modernExtend');
const definition = {
zigbeeModel: ['TS0601'],
model: 'TS0601',
vendor: '_TZE200_na5qlzow',
description: 'Automatically generated definition',
extend: [identify(), iasZoneAlarm({"zoneType":"generic","zoneAttributes":["alarm_1","alarm_2","tamper","battery_low"]}), battery(), illuminance()],
meta: {},
};
module.exports = definition;
Hello can you add the necessary definition for an AVATTO ZDMS16-2
It is a Zigbee Module 2 channels Dimmer.
This is the generated external converter :
{
"last_seen": "2025-11-04T18:34:39.089Z",
"linkquality": 160,
"device": {
"applicationVersion": 78,
"dateCode": "",
"friendlyName": "0xa4c1385b98ce2ed7",
"hardwareVersion": 1,
"ieeeAddr": "0xa4c1385b98ce2ed7",
"manufacturerID": 4417,
"manufacturerName": "_TZE284_jtbgusdc",
"networkAddress": 12724,
"powerSource": "Mains (single phase)",
"stackVersion": 0,
"type": "Router",
"zclVersion": 3
}
}
const definition = {
zigbeeModel: ['TS0601'],
model: 'TS0601',
vendor: '_TZE284_jtbgusdc',
description: 'Automatically generated definition',
extend: [],
meta: {},
};
module.exports = definition;
Thanks for your efforts.
Kind regards.
Hello can you add the necessary definition for an AVATTO ZDMS16-2 It is a Zigbee Module 2 channels Dimmer. This is the generated external converter :
{ "last_seen": "2025-11-04T18:34:39.089Z", "linkquality": 160, "device": { "applicationVersion": 78, "dateCode": "", "friendlyName": "0xa4c1385b98ce2ed7", "hardwareVersion": 1, "ieeeAddr": "0xa4c1385b98ce2ed7", "manufacturerID": 4417, "manufacturerName": "_TZE284_jtbgusdc", "networkAddress": 12724, "powerSource": "Mains (single phase)", "stackVersion": 0, "type": "Router", "zclVersion": 3 } }
const definition = { zigbeeModel: ['TS0601'], model: 'TS0601', vendor: '_TZE284_jtbgusdc', description: 'Automatically generated definition', extend: [], meta: {}, };
module.exports = definition;
Thanks for your efforts. Kind regards.
That manufacturerID is already supported. Are you using the last version of Zigbee2MQTT?
Could anyone more skilled than me in Z2M add the new Namron Zigbee Thermostat?
Article No: 4512776
Name: Namron Zigbee termostat for panelovn PRO hvit
Product page link: https://www.elektroimportoren.no/namron-zigbee-termostat-for-panelovn-pro-hvit/4512776/Product.html
I have a Namron Zigbee panel heater released before the new thermostats + oven line were released. I suspect this new thermostat would act much the same way as the existing Namron 540139X would (https://www.zigbee2mqtt.io/devices/540139X.html)
If i could help in any way, please let me know.
Generated external definition (from Z2M Dev Console)
import * as m from 'zigbee-herdsman-converters/lib/modernExtend';
export default {
zigbeeModel: ['Panel Heater'],
model: 'Panel Heater',
vendor: 'NAMRON AS',
description: 'Automatically generated definition',
extend: [m.electricityMeter()],
};
{
"description": "Automatically generated definition",
"exposes": [
{
"access": 5,
"description": "Instantaneous measured power",
"label": "Power",
"name": "power",
"property": "power",
"type": "numeric",
"unit": "W"
},
{
"access": 5,
"description": "Measured electrical potential value",
"label": "Voltage",
"name": "voltage",
"property": "voltage",
"type": "numeric",
"unit": "V"
},
{
"access": 5,
"description": "Instantaneous measured electrical current",
"label": "Current",
"name": "current",
"property": "current",
"type": "numeric",
"unit": "A"
},
{
"access": 5,
"description": "Sum of consumed energy",
"label": "Energy",
"name": "energy",
"property": "energy",
"type": "numeric",
"unit": "kWh"
},
{
"access": 1,
"category": "diagnostic",
"description": "Link quality (signal strength)",
"label": "Linkquality",
"name": "linkquality",
"property": "linkquality",
"type": "numeric",
"unit": "lqi",
"value_max": 255,
"value_min": 0
}
],
"model": "Panel Heater",
"options": [
{
"access": 2,
"description": "Calibrates the power value (percentual offset), takes into effect on next report of device.",
"label": "Power calibration",
"name": "power_calibration",
"property": "power_calibration",
"type": "numeric",
"value_step": 0.1
},
{
"access": 2,
"description": "Number of digits after decimal point for power, takes into effect on next report of device. This option can only decrease the precision, not increase it.",
"label": "Power precision",
"name": "power_precision",
"property": "power_precision",
"type": "numeric",
"value_max": 3,
"value_min": 0
},
{
"access": 2,
"description": "Calibrates the voltage value (percentual offset), takes into effect on next report of device.",
"label": "Voltage calibration",
"name": "voltage_calibration",
"property": "voltage_calibration",
"type": "numeric",
"value_step": 0.1
},
{
"access": 2,
"description": "Number of digits after decimal point for voltage, takes into effect on next report of device. This option can only decrease the precision, not increase it.",
"label": "Voltage precision",
"name": "voltage_precision",
"property": "voltage_precision",
"type": "numeric",
"value_max": 3,
"value_min": 0
},
{
"access": 2,
"description": "Calibrates the current value (percentual offset), takes into effect on next report of device.",
"label": "Current calibration",
"name": "current_calibration",
"property": "current_calibration",
"type": "numeric",
"value_step": 0.1
},
{
"access": 2,
"description": "Number of digits after decimal point for current, takes into effect on next report of device. This option can only decrease the precision, not increase it.",
"label": "Current precision",
"name": "current_precision",
"property": "current_precision",
"type": "numeric",
"value_max": 3,
"value_min": 0
},
{
"access": 2,
"description": "Calibrates the energy value (percentual offset), takes into effect on next report of device.",
"label": "Energy calibration",
"name": "energy_calibration",
"property": "energy_calibration",
"type": "numeric",
"value_step": 0.1
},
{
"access": 2,
"description": "Number of digits after decimal point for energy, takes into effect on next report of device. This option can only decrease the precision, not increase it.",
"label": "Energy precision",
"name": "energy_precision",
"property": "energy_precision",
"type": "numeric",
"value_max": 3,
"value_min": 0
}
],
"source": "generated",
"supports_ota": false,
"vendor": "NAMRON AS"
}
Hi,
I just purchased the EcoDim DIM.06 dimmer but found that is not supported yet.
Would it be possible to add this one?
Thanks in advance.
https://www.123led.nl/EcoDim-Zigbee-stekkerdimmer-0-100W-Fase-afsnijding-RC-EcoDim-DIM-06-i7926-t4329.html
{
"description": "Automatically generated definition",
"exposes": [
{
"features": [
{
"access": 7,
"description": "On/off state of this light",
"label": "State",
"name": "state",
"property": "state",
"type": "binary",
"value_off": "OFF",
"value_on": "ON",
"value_toggle": "TOGGLE"
},
{
"access": 7,
"description": "Brightness of this light",
"label": "Brightness",
"name": "brightness",
"property": "brightness",
"type": "numeric",
"value_max": 254,
"value_min": 0
}
],
"type": "light"
},
{
"access": 2,
"description": "Triggers an effect on the light (e.g. make light blink for a few seconds)",
"label": "Effect",
"name": "effect",
"property": "effect",
"type": "enum",
"values": [
"blink",
"breathe",
"okay",
"channel_change",
"finish_effect",
"stop_effect"
]
},
{
"access": 7,
"category": "config",
"description": "Controls the behavior when the device is powered on after power loss",
"label": "Power-on behavior",
"name": "power_on_behavior",
"property": "power_on_behavior",
"type": "enum",
"values": [
"off",
"on",
"toggle",
"previous"
]
},
{
"access": 1,
"category": "diagnostic",
"description": "Link quality (signal strength)",
"label": "Linkquality",
"name": "linkquality",
"property": "linkquality",
"type": "numeric",
"unit": "lqi",
"value_max": 255,
"value_min": 0
}
],
"model": "eco-dim06-zigbee",
"options": [
{
"access": 2,
"description": "Controls the transition time (in seconds) of on/off, brightness, color temperature (if applicable) and color (if applicable) changes. Defaults to
0(no transition).","label": "Transition",
"name": "transition",
"property": "transition",
"type": "numeric",
"value_min": 0
},
{
"access": 2,
"description": "State actions will also be published as 'action' when true (default false).",
"label": "State action",
"name": "state_action",
"property": "state_action",
"type": "binary",
"value_off": false,
"value_on": true
}
],
"source": "generated",
"supports_ota": false,
"vendor": "EcoDim BV"
}